S11型35kV级电力变压器是在总结以往“7” 型、原“9”型电力变压器设计制造经验的基础上更新换代的,新产品采用了新?#38469;酢?#26032;工艺、新材料、新组件、新结构,不仅节能节材,而?#20197;?#34892;安全可靠,已在城乡电网建设与改造工程项目?#22411;?#33616;使用。

S11 35kV Power Transformer is upgrading on the basis of summarizing the design experience of the past type “7” and the original type “9” power transformer. The new product adopts new technologies, new workmanship, new materials, new components and new structure. It will save not only energy and materials but also operation is safe and reliable, it has been recommended to use in urban and rural power grid construction and renovation projects.

产品结构
Product Structure

铁心设计时合理选择磁通密度,保证正常工作电压下有一定的裕度,在系统电压偏高时不出现磁饱和现象,硅?#21046;?#26412;身的磁滞振动小。铁心材质选用优质冷轧晶粒取向硅?#21046;?#38081;心为三相三柱式、铁心柱多级阶梯圆柱形;全斜接缝阶梯多级叠片、无?#35013;?#25166;;夹件可选板式或槽钢结构,减少焊接量,增加夹件强度,并通过上下夹件的拉螺杆拉紧器身,结构简单,增加绕组的抗短路能力;同时采取合理的减振措施。并控制叠片的参差离缝,?#22266;?#24515;磁阻小,漏磁小。6300KVA及以下的铁轭与心柱截面形状相同,8000KVA及以上铁轭为“D”型,以减少角重,降低损耗,最小级片加宽,增加铁轭与夹件接触面,改善铁轭的夹紧状态。

绕组内部采用油导向结构/轴向油道,有利于散热,可大幅度降低铜油温差,使内部各区域的热油能充分的冷却,降低绕组的最热点温升;无载调压变压器其分接范围仅为±3×2.5%,故不独立设置调压绕组,分接引线置于主线圈本体中部,从而简化结构。高低压绕组设计时采用新开发的主纵绝缘结构,严格控制安匝分布/冲击分布,降低材料用量;低压绕组直接绕制在高强度的绝缘纸筒上,高、低压绕组在绕制时采用辐向、轴向压紧装置,增加绕组的压紧力,减少运行中的收缩;并用内外撑条进行紧固,加强支撑,提高绕组稳定?#35029;乐?#20854;失稳变形;绕组可按要求进行浸漆处理和分相整体套装;且改进压板结构,加强端部压紧,以增强机械强度,提高承受短路能力。

改进引线夹紧结构,采用木材与绑扎相结?#31995;?#24418;式,使引线固定牢固不位移和松动。

器身采用新的绝缘框架,进行复合场强计算,保证足够的绝缘强度,具有较高的填充系数;严格控制器身干燥结束后在大气暴露的时间,避免受?#20445;?#22120;身与油箱采用“刚性定位?#20445;?#25552;高产品运输中承受冲击的能力。

油箱按免吊心结构设计,现场可直接安装。布局紧凑,造型美观、结构新?#20445;?#21487;为钟?#36136;?#25110;折边瓦楞式结构(平顶式),简化结构便于加工;箱体选用宽幅钢板,减少焊缝,增加机械强度;所有密封面(箱沿、法兰)进行机械加工,采用“O”型密封结构?#20048;?#28183;漏;变压器油箱及散热器应能承受0.05Mpa的压力,并无渗漏、损伤现象。

主体?#31995;?#38468;件应有:端子箱采用不锈钢箱体,密封良好,便于接线;温度计座(焊在箱盖

上)二根,置于油箱长轴方向的两端;气体继电器、温度计、压力释放阀引线电缆支架应固定在箱体上,接线引到接线端子箱内。但所有装在变压器本体?#31995;?#38468;件,最低部件不得低于箱底水平线。


Iron core chose the magnetic flux density reasonably when it was designed. To ensure there is some margin under normal working voltage and no magnetic saturation when the system voltage was too high. The material of the iron core is good quality cold-rolled grain oriented silicon steel sheet; The iron core is three phase, three column and multi ladder cylindrical column core pole; The clamping piece can choose the structure of plate or channel steel, to reduce the amount of the welding and increase its strength. To strain the body by the upper and lower tie bolt, the structure is simple and an increase of anti-short circuit capacity of the winding. At the same time, to take reasonable measures of damping, besides this, to control the irregular seams of the lamination which make the small magnetic resistance and leakage. The section of the yoke is same with the core pole below 6300KVA, 8000KVA or above it, the yoke is “D” type. The purpose is to reduce the weight and waste, the smallest class film is widened, to increase the contact surface between yoke and clamping piece and improve the state of the clamping of the yoke.

Internal of the winding adopts the oil guide structure/ axial direction oil duct, that is conducive to heat dissipation and greatly reduce the copper oil temperature, so that the oil of all regions of the internal can be cooling to reduce the hottest temperature spot of the winding. The tap scope of the no-load transformer is only ±3×2.5%, so we don’t set up the voltage regulation union independently, the tap line is placed in the center of main coil, thus it simplifies the structure. The high-low voltage adopts the principal insulation structure while designing. To control the distribution of ampere turns and impact strictly, thereby the amount of the materials will be reduced. The low voltage winding is winded around the high-strength paper tube directly, the high-low voltage winding adopts the radial and axial direction devices while winding, to increase the pressing force and reduce the constriction in working; At the same time, to tighten the internal and external support bars to make a support, so that the stability of winding is improved, the instability and the deformation is prevented. The winding can be treated with dip coating and packed with division phase; In order to enhance its mechanical strength and improve the ability of bearing the short-circuit, to change the structure of the pressing plate and strengthen the ends.

To improve the lead wire clamping structure, and to adopt the shape of wood combining with colligation which makes the lead wire firm and fixed.

The body adopts the new insulation flame to calculate the composite field intensity and ensure adequate insulation strength, which has large filling coefficient; To control strictly the time of the dried body exposed in the atmosphere and to keep from moisture; The body and the tank adopt “Rigidly Positioned” to improve the capacity of product against the impact during the transportation.

The tank is designed by the structure of suspended core free, it is can be installed directly at site. It has compact layout, beautiful styling and novel structure, it also can be bell or fold corrugated structure (flat-top type), in order to process easily to simplify the structure; Selection of wide steel plate to reduce the weld joint and increase the mechanical strength; To make mechanical processing for all the sealing faces (edge of the box, flange), it adopts “O” type seal structure to prevent the leakage; The tank and the radiator of the transformer should withstand 0.05Mpa pressure, and there is no leakage and injury.

Accessories of main body should contain: the terminal box adopts the stainless steel box which has good leak tightness and easy to connect; two thermometer seats (soldering on the cover) are placed on the two ends of the macro axis of the tank; The gas relay, the thermometer, pressure release valve wire cable support should be fixed on the body, the line is connected into the terminal box. However, the lowest part of all the accessories installing on the body of the transformer can not lower than the horizontal line of the body bottom.


?#38469;?#21442;数
Product Structure

未标题-10.jpg


订货须知
ordering Information

订货方在订货时应给本公司提供与产品有关的下列数据

1. 型号规格       

2. 额定容量        

3. 相数      

4. 频率     

5. 电压组合/分接范围

6. 联结组标号     

7. 短路阻抗     

8. 油箱结构/冷却方式     

9. 其它特殊要求/使用条件


In order to serve you better, please offer the following parameters when you are choosing our products.

1. Type 

2. Rated Capacity      

3. Phase No.     

4. Frequency

5. Voltage Combination/ Tapping Range    

6. Union Symbol    

7. Short Circuit Impedance

8. Tank Structure/ Cooling Model     

9. Other Special Requests/ Conditions of Use